Products
Nanopositioning Systems
>>Micropositioning Systems
General Microscopy
Single Molecule Microscopy
AFM & NSOM
Nanometer Measurement
Vacuum Compatible Instruments
Custom/OEM
Questions?
E-Mail Us |
All Mad City Labs micropositioning stages are compatible with Mad City Labs nanopositioning systems. Custom designs are available. Click the category headings to expand or collapse the product tables. |
|
Microscope Stages: Motorized and Manual
Product |
Description |
Applications |
Mad-Deck™ |
The Mad-Deck™ is a versatile stage platform designed for advanced microscopy techniques that require free access above and below the sample plane. |
optical microscopy |
MicroStage Series
|
Precision stepper motor driven micropositioner for use with inverted optical microscopes with up to 25 mm of travel per axis, optional integrated linear encoders that provide 50 nm resolution position measurements, and a minimum step size of 95 nm. |
optical microscopy |
Manual MicroStage Series
|
Low profile, two-axis microscopy stage specifically designed to act as a secure base for high resolution nanopositioning stages. |
optical microscopy |
Manual MicroStage-LT Series |
Longer XY travel (up to 50mm), an aperture design that allows rotation of the microscope's objective nosepiece, continuous internal position locking, and excellent stability |
optical microscopy |
Manual MicroStage-BX |
Fits onto Olympus upright BX microscopes, 25mm motion in XY, continuous internal position locking, and excellent stability |
optical microscopy |
Nano-View®/M Series |
Fully integrated nanopositioning and micropositioning systems for use with inverted optical microscopes that offer long range manual micropositioning in two axes, combined with a 2-axis or 3-axis nanopositioner |
confocal and fluorescence imaging, single molecule imaging spectroscopy, optical trapping, |
Nano-View® Series
|
Fully integrated nanopositioning and micropositioning systems for use with inverted optical microscopes, combined with a high resolution, 2-axis or 3-axis nanopositioner |
confocal and fluorescence imaging, single molecule, particle tracking, optical trapping |
MCL-MANNZ |
Integrated micro-nanopositioning system for use with inverted optical microscopes, combining a manual micrometer driven, two axis, linear motion stage with a high resolution z-axis nanopositioner. |
optical microscopy, confocal imaging, fluorescence imaging, |
MCL-MOTNZ |
Value priced positioning system for use with inverted optical microscopes, combining a stepper motor XY linear motion stage with a closed loop high resolution Z-axis nanopositioning system. |
optical microscopy, confocal imaging, fluorescence imaging, single molecule spectroscopy |
|
|
Motorized Micropositioners
Product |
Description |
Applications |
MMP Series
|
Precision, stepper motor driven, micropositioning system for high precision positioning for a variety of applications. Long range linear positioning is provided in one, two or three axis configurations with high resolution and excellent repeatability. |
complex, programmed motion control; high precision positoining; automation |
SPM-MZ
|
Precision aligned, highly stable single axis micropositioner designed as a Z-axis approach for scanning probe microscopes. |
scanning probe microscopy, nanomanipulation |
MMP-UHV50 |
Precision coarse positioning for vacuum application |
Vacuum motion |
|
|
Integrated Nanopositioning and Micropositioning Stages
Product |
Description |
Applications |
Nano-View®/M Series |
Fully integrated nanopositioning and micropositioning systems for use with inverted optical microscopes that offer long range manual micropositioning in two axes, combined with a 2-axis or 3-axis nanopositioner |
confocal and fluorescence imaging, single molecule microscopy and , optical trapping, optical tweezers. |
Nano-View® Series
|
Fully integrated nanopositioning and micropositioning systems for use with inverted optical microscopes, combined with a high resolution, 2-axis or 3-axis nanopositioner |
confocal and fluorescence imaging, single molecule microscopy and spectroscopy, particle tracking, optical trapping |
MCL-MANNZ |
Integrated micro-nanopositioning system for use with inverted optical microscopes, combining a manual micrometer driven, two axis, linear motion stage with a high resolution z-axis nanopositioner. |
microscopy, confocal, fluorescence imaging, single molecule imaging |
MCL-MOTNZ |
Value priced positioning system for use with inverted optical microscopes, combining a stepper motor XY linear motion stage with a closed loop high resolution Z-axis nanopositioning system. |
optical microscopy, confocal imaging, fluorescence imaging, single molecule imaging |
|
|
Micropositioning and Nanopositioning Accessories
Product |
Description |
Applications |
Accessories
|
Accessories compatible with Mad City Labs nanopositioning and micropositioning systems including microscope mounting adapters, biological sample holders, objective lens extender tubes, rack mount kits, and joystick/gamepad controllers for the Nano-Drive® and MicroDrive™ controllers. |
Nanopositioning and Micropositioning |
|
|